Acoustic panel mounting systems are just as significant as the thickness of the material or its sound absorption coefficient. The choice of a specific installation method makes it possible to alter how PET felt interacts with sound waves, effectively transforming standard wall cladding into an advanced sound-absorbing system. By intentionally adjusting the distance from the wall or combining panels with additional layers, architects gain the flexibility to precisely shape acoustics to meet the specific challenges of a given space. In this article, we discuss the three most common mounting systems and explain which environments are best suited for each one.

How do mounting systems affect the effectiveness of acoustic panels?
The effectiveness of acoustic panels is not a fixed value; it varies depending on how they are installed within a partition. The same material can function within a narrow frequency range or become part of a broadband system, depending on factors such as the arrangement of layers, the distance from the wall, or the inclusion of additional absorbing material.
When mounted directly, a panel absorbs energy primarily in the mid-to-high frequency range, which helps reduce echoes and improve speech clarity. Introducing an air gap increases the distance the sound wave must travel, thereby enhancing absorption efficiency at lower frequencies. Furthermore, employing a layered configuration—such as combining a PET panel with mineral wool—significantly broadens the effective frequency range and noticeably reduces reverberation time in larger spaces. Consequently, when designing interior acoustics, the focus is not merely on individual product specifications, but on the entire system.
System 1 – mounting acoustic panels directly to the wall
Direct mounting is the simplest and most common method for installing acoustic panels. The panel is attached directly to a rigid surface—typically a masonry, drywall, or concrete wall—without any additional spacing or intermediate layers. This approach allows for a quick improvement in a room’s acoustic comfort, particularly by reducing echoes and the excessive “sharpness” of sound reflections.
Application of direct mounting for acoustic panels
This system is effective primarily in situations where reflections in the speech frequency range are a problem. It is suitable for use in:
- offices,
- small meeting rooms,
- corridors,
- service premises,
- small offices.
What should you pay attention to when mounting acoustic panels directly to a wall?
When mounted directly against a partition, effectiveness at lower frequencies is limited. In larger spaces, this may mean that—despite improved speech intelligibility—a persistent “boomy” quality or a heavier sound remains. Direct mounting is therefore a solution suited to specific circumstances: namely, when the goal is to improve conversational comfort rather than to achieve full control over reverberation time.

System 2 – acoustic panels with an air gap
In a system featuring an air gap, the acoustic panel is mounted at a small distance from the wall. The resulting space—even if only a few centimeters wide—significantly alters how the entire setup functions. It is not the panel itself that changes, but rather the conditions under which it interacts with sound waves.
How does an air gap affect the effectiveness of acoustic panels?
The gap ensures that a sound wave, after passing through the material, is not immediately dampened by a hard barrier. Instead, it reflects off the barrier and travels back into the panel’s structure. Extending the path of the acoustic energy in this way allows for significantly more effective sound absorption—particularly in the lower frequency ranges, which often remain largely uncontrolled when materials are mounted directly against a surface.
The result is a more balanced acoustic profile within the room. The sound becomes more stable—less “flat”—and the differences between various zones within the same space are less noticeable.
Where is it advisable to install acoustic panels with a gap (offset from the wall)?
A system with an air gap is recommended primarily for spaces with a larger volume, or in areas where acoustics directly affect work comfort:
- open-plan offices,
- conference rooms,
- coworking spaces,
- rooms with increased ceiling height.
In such interiors, simply reducing echoes is not enough; it is necessary to control how sound propagates throughout the entire volume of the space. For this reason, a wall-mounted system with a gap often serves as part of a broader solution—complemented by acoustic ceilings or suspended acoustic islands that support the function of the vertical partition.
System 3 – PET panel with a 50 mm layer of mineral wool
In a layered system, a PET panel works in conjunction with an additional layer of absorbent material—most commonly 50 mm of mineral wool. In this configuration, the panel becomes part of an advanced acoustic system designed for the complete control of reverberation time.

How does a layer of mineral wool affect the effectiveness of acoustic panels?
Adding a layer of wool significantly alters the way sound is absorbed. A material with higher density captures wave energy across a broader frequency range—including lower tones that often remain partially uncontrolled in other systems. In this configuration, the PET panel serves an aesthetic and supportive function, while the absorbent layer is responsible for the primary reduction of acoustic energy.
The result is a broadband absorber that reduces reverberation time and stabilizes acoustic conditions throughout the entire volume of a room. This solution is particularly important in large-volume spaces, where sound can reflect repeatedly off hard surfaces.
Where should acoustic panels with mineral wool be used?
A PET panel with a layer of mineral wool is best suited for:
- offices with a large volume,
- libraries and reading rooms,
- lecture and conference halls,
- in spaces requiring enhanced speech intelligibility,
- interiors of a semi-public and public nature.
In such projects, the goal is not merely to reduce echo, but to deliberately shape the acoustic parameters of the entire interior. A layered system makes it possible to achieve an effect that is difficult to attain through direct mounting or installation with a gap alone.
Laboratory testing of acoustic panels – ASTM and PN-EN ISO standards
The effectiveness of acoustic panel mounting systems should be analyzed based on measurement data. In commercial and public projects, acoustic parameters must be verified through laboratory testing in accordance with applicable standards. This allows the panel specifications to be assessed objectively and compared with other solutions used in architectural projects.
Felthe acoustic panels have undergone comprehensive laboratory testing in accordance with ASTM C423-23 and PN-EN ISO 11654:1999 standards. For architects, these standards serve as a basis for evaluating sound-absorbing materials:
- ASTM C423-23 specifies the method for measuring the sound absorption coefficient and allows for the determination of the NRC (Noise Reduction Coefficient) value.
- PN-EN ISO 11654:1999 classifies acoustic materials according to the αw coefficient, assigning them absorption classes (A, B, C, D, E).

What does the NRC rating mean?
The NRC (Noise Reduction Coefficient) indicates a material’s average ability to absorb sound within the frequency range relevant to speech. A higher value signifies greater reduction of acoustic energy in a room.
For PET panels, effectiveness varies depending on the mounting system:
- NRC = 0.30 (9 mm / direct mounting),
- NRC = 0.40 (12 mm / direct mounting),
- NRC = 1.05 (12 mm / multilayer system with 50 mm mineral wool).
The αw coefficient and absorption classes of acoustic panels
The standard PN-EN ISO 11654:1999 introduces a classification of materials based on the αw coefficient. In practice, this allows a panel to be assigned to one of several absorption classes – ranging from E to A.
Test results for PET panels:
- αw = 0.25 (H) – 9 mm / direct mounting,
- αw = 0.25 (MH) – 12 mm / direct mounting,
- αw = 1.00 – 12 mm + 50 mm mineral wool.
Achieving an αw value of 1.00 corresponds to Class A and confirms that the layered system functions as a broadband absorber, effective even in more demanding spaces.
How do you choose an acoustic panel mounting system for a specific type of space?
Selecting the right solution should begin with an analysis of several key factors that determine the effectiveness of acoustic treatment.
1. Defining the acoustic problem
It all begins with a question: what kind of acoustic problem are we dealing with? In some interiors, the goal is simply to soften reflections from hard surfaces. In others, it is about reducing the reverberation time and stabilizing conditions throughout the entire space.
2. Analysis of finishing materials
The next step should be an analysis of the finishing materials. A space featuring large amounts of glass, concrete, stone, or suspended ceilings with low sound absorption will create acoustic conditions entirely different from those in an interior filled with built-in furniture, textiles, and sound-diffusing elements. In such cases, the mounting system must compensate for the rigid nature of the surfaces.

3. Geometry and proportions of the interior
The proportions of the interior—its height, length, and width—are also important.
- High-ceilinged spaces require systems that allow panels to function throughout the entire volume (e.g., suspended or island-style systems), rather than just at the users’ eye level.
- For low and compact building forms, wall-mounted systems—installed directly onto the partitions—are a better solution.
4. Intensity of use
The way a space is used is also significant. An interior occupied by a dozen or so people engaged in conversation behaves differently than an office used only occasionally. The intensity of use translates directly into an acoustic load, which the installation system should take into account.
- Conference rooms/open-plan spaces: a large number of people creates a high acoustic load, which necessitates a denser and more efficient mounting system.
- Gabinety indywidualne: przy sporadycznym użytkowaniu system może być bardziej punktowy i nastawiony na estetykę.
Acoustic panel mounting system as an element of the design
An acoustic panel serves as a foundation, but the final result depends on how it is integrated into the interior’s structure and detailing. For this reason, the choice of a mounting system should be considered an integral part of the design. Should any questions arise during the conceptual phase, our team is here to help select the right technology—ensuring that the properties of the felt are utilized as effectively as possible within the context of your specific project.